Finden Sie schnell canon spiegelreflexkamera test für Ihr Unternehmen: 63 Ergebnisse

KV50-200 MK3 Test System

KV50-200 MK3 Test System

0-50kV output voltage 5kVA output capability Key operated supply switch to prevent unauthorised operation Dual overload protection Variable electronic trip – 10-110% of rated output Voltage and current metering External interlock circuit Zero-volt interlock Visual indication of test piece failure The KV50-200 MK2 Test System is a high power, high voltage ac test set designed for insulation testing. This system is equally suited to both development and routine testing of electrical insulation systems and plant. The equipment consists of a control unit and a separate oil filled high voltage transformer, linked by 5 meter supply and control cables. The control unit is fitted with a comprehensive range of facilities for control, metering and protection. The system includes a secondary tap metering as standard to ensure accurate voltage metering. The output voltage and current are displayed on large, linear analogue instruments, and a variable electronic trip is provided, allowing the trip current to be set to 10-110% of rated output. The high voltage transformer is housed in an oil-filled steel tank fitted with swivel castors for mobility. The units use a low-discharge oil-filled bushing for the HV output. The KV50-200 MK2 Test System is equally suited to testing capacitive, resistive or inductive test objects. The output of the units are protected by variable electronic trips monitoring the output current, and a fixed over-current trip on the primary of the output transformer. The variable trip is adjustable in 10% steps between 10% and 110% of the rated output current. The input and control supplies are protected by fuses. An earth terminal is provided on the transformer which must be connected to a low impedance local earth. WEIGHT 37 kg DIMENSIONS 370 × 480 × 290 mm TRANSFORMER WEIGHT 220 kg TRANSFORMER DIMENSIONS 570 x 500 x 1020 mm SUPPLIED ACCESSORIES Supply lead Spare fuse set Operating manual Earth lead
Testo 835-T2 Infrarot-Hochtemperatur-Messgerät

Testo 835-T2 Infrarot-Hochtemperatur-Messgerät

Neues, hochgenaues Infrarot-Messgerät mit ein paar ganz besonderen Funktionen: - Möglichkeit zur automatischen Emissionsgrad-Bestimmung, sofern ein optionaler Oberflächenfühler mit angeschlossen ist - Messung bis 1500°C, also auch an flüssigen oder glühenden Metallen - Online-Messung über einen PC und die kostenlos herunterladbare Software Das präzise, leicht zu bedienende Infrarot-Messgerät für den Hochtemperaturbereich bis +1500°C aus der neuen Testo 835 Serie mit 4-Punkt-Laser und integriertem Messwertspeicher. Die abgespeicherten Daten können anschließend am PC bequem ausgewertet werden. Das neue Testo 835-T2 mit erweitertem Messbereich und einer Optik von 50:1 eignet sich ideal für die Temperaturüberwachung in der Glas-, Keramik- und Metallindustrie. Es verfügt zusätzlich über eine integrierte Emissionsgrad-Tabelle. Ein Typ K-Temperaturfühler kann bei Bedarf angeschlossen werden (Fühler nicht im Lieferumfang enthalten). Technische Daten: Optik 50:1 Blick 4-Punkt-Laser Spektralbereich 8 bis 14 µm Messbereich Infrarot -10 bis +1500 °C Genauigkeit +/-2,0 °C o. +/- 1% v. Mw. Auflösung 0,1° C (-10 bis 999,9 °C), 1°C (+1000 bis +1500°C) Messbereich Sensortyp Typ K (NiCr-Ni) -50 bis +1000°C Genauigkeit +/- (0,5 °C + 0,5% v. Mw.) Auflösung 0,1 °C Emissionsfaktor 0,1 bis 1,00 (Schritt 0,01) Emissionsgradtabelle 20 Messwerte speicherbar Laserpunkt Ein/Aus Speicher 200 Messwerte speicherbar Alarm IR-Temperatur, TE-Temperatur Alarmsignal akustisch, optisch Betriebstemperatur -20 bis +50°C Lagertemperatur -30 bis +50°C Gehäusematerial ABS + PC BatterieTyp 3 x Batterie Typ AA (oder USB-Anschluss mit PC-Software Abmessung (LxHxB) 193 x 165 x 63 mm Gewicht 514 g Display Dot-Matrix Garantie 2 Jahre Testo 835-T2, Infrarot-Hochtemperatur-Messgerät, 4-Punkt-Lasermarkierung, Messdatenverwaltung, inkl. Batterien und Kalibrierprotokoll
xiC camera series - Small, light, versatile. With incredible image quality.

xiC camera series - Small, light, versatile. With incredible image quality.

The xiC camera line is highly versatile with a wide range of the most modern global shutter CMOS sensors up to 24.5 Mpix in resolution. The ultra-compact form factor, barely larger than the C-mount, combined with micro-B, type-C, and flex ribbon connectors make these cameras the perfect fit for various applications, especially for automation and embedded vision systems. For the same form-factor and sensor options, but increased bandwidth of 10 Gbit/s resulting in doubled frame rates, there is the xiX family. - Compact cameras with Sony Pregius™ sensors - 26 x 26 x 33 mm - Fast speed from 2.3 Mpix at 165 FPS to 12 Mpix at 31 FPS - Cool economy - Low power consumption with under 3 watts
TIGRES Teststifte für Oberflächenspannungsprüfung, Bestimmung der Oberflächenspannung

TIGRES Teststifte für Oberflächenspannungsprüfung, Bestimmung der Oberflächenspannung

Unsere Testtinten gibt es auch im praktischen Stiftformat. Bei Testtinte handelt es sich um genormte Prüfflüssigkeiten zur Ermittlung der Oberflächenenergie des zu beschichtenden Substrats. Testtinten werden zur prozessbegleitenden Kontrolle sowie zur Wareneingangsprüfung und Qualitätssicherung eingesetzt. Die Flüssigkeiten mit schrittweise steigender Oberflächenspannung werden auf die Produktoberfläche aufgetragen. Die Oberflächenenergie des Substrats ist annähernd gleich der Oberflächenspannung der Testtinte, wenn der aufgetragene Flüssigkeitsfilm für 2 Sekunden die Oberfläche benetzt.
Testmanagement mit NI-TestStand /Sequenzielles Testen / Testsequenzer / Certified TestStand Architect

Testmanagement mit NI-TestStand /Sequenzielles Testen / Testsequenzer / Certified TestStand Architect

Als NI-Alliance Partner nutzen wir NI-TestStand und NI-LabVIEW für die Testautomation. Python, C/C++ und Microsoft PowerBI können ergänzend eingesetzt werden NI-TestStand ist die Industriestandard Test-Management Software und wird von den Entwicklern und Architecten bei Merecs Engineering mit viel Erfahrung eingesetzt. -Anforderungsanalyse auf Basis der zu prüfenden DUT-Eigenschaften -Erarbeitung von Testfällen in Kooperation -Sequenzentwicklung in TestStand -Intuitive Custom User Interfaces -Paralleles Testen vieler DUTs -Reporting (SQL-Datenbanken uvm.) -Schulungen & Workshops Unsere Entwickler verfügen über die Zertifikate CLA (Certified TestStand Architect) und CLD (Certified TestStand Developer). Zusätzlich arbeiten wir mit NI-LabVIEW, Python, C/C++ (Embedded) und Microsoft PowerBI
Teststifte für Oberflächenspannungsprüfung Rapidtest 38®  TEST Stift

Teststifte für Oberflächenspannungsprüfung Rapidtest 38® TEST Stift

Mit dem Rapidtest 38® lässt sich feststellen, ob die Vorbehandlung von Polyolefinen (Polypropylen, Polyethylen, Polybutylen) einen Effekt gezeigt hat. Der mit Rapidtest 38® aufgetragener Strich trocknet in Sekundenschnelle an, er muss/kann nicht mehr abgewischt werden.
Filtertestgerät „it-01“ Hohe Genauigkeit und Reproduzierbarkeit von Testergebnissen

Filtertestgerät „it-01“ Hohe Genauigkeit und Reproduzierbarkeit von Testergebnissen

Das Filtertestgerät „it-01“ von Flow Test GmbH dient zur Integritätsprüfung von Membranfiltern und zur Messung unbekannter Volumina. Es ist leicht, kompakt und portabel, verfügt über ein robustes, wasserdichtes Edelstahlgehäuse und bietet hohe Genauigkeit und Reproduzierbarkeit von Testergebnissen. Das Gerät ist anwenderfreundlich und ermöglicht die Filterprüfung am Gerät sowie den Betrieb von Pressluftventilen. Es ist vollständig mit 21 CFR Part II kompatibel und bietet verschiedene Testarten wie Diffusionstest, Druckabfall-Test und Bubble Point Test.
Versuchsanlagen für innovative Abluftlösungen (Pilotierung)

Versuchsanlagen für innovative Abluftlösungen (Pilotierung)

Mit den Versuchsanlagen der Stooss abluftconsulting GmbH können Abluftsysteme unter realen Bedingungen getestet und optimiert werden. Unsere Pilotierungsdienste ermöglichen es, neue Technologien und Prozesse sicher und effizient zu erproben, bevor sie in den Betrieb integriert werden. Eigenschaften & Vorteile: Risikoloses Testen: Simulation realer Bedingungen ohne Betriebsunterbrechung. Innovationsförderung: Validierung neuer Technologien und Abluftkonzepte. Effizienzsteigerung: Optimierung von Prozessen vor der Implementierung. Individuelle Anpassung: Maßgeschneiderte Pilotanlagen für spezifische Anforderungen.
Machbarkeitsstudien & Richtversuche​

Machbarkeitsstudien & Richtversuche​

Sie wissen noch nicht, ob Ihr Wunschkonzept die richtige Lösung für Ihre Richtaufgabe ist? Wir helfen Ihnen, dies herauszufinden. In unserem Testzentrum führen wir gern Machbarkeitsstudien und Richtversuche für Sie durch.
Eiswasser-Schocktest

Eiswasser-Schocktest

Der Prüfling wird durch Umluft auf bis zu +200°C erwärmt und anschließend, durch Eintauchen in ein kaltes Prüfmedium, geschockt. Diese Prüfung simuliert die Lebensdauerbeanspruchung und dient zur Absicherung der Funktion bei einem schockartigen Abkühlen durch Eintauchen. Das Ziel der Simulation ist es, den Prüfling vor Eindringen von Wasser zu schützen, um die Funktionsfähigkeit sicherzustellen. Die anschließende Auswertung erfolgt über eine kontinuierliche Parameterdokumentat. Wir beraten Sie gerne individuell!
Medizinische Tests

Medizinische Tests

Mithilfe unseres Equipments können verschiedene Medical Device Testings und spezifische Messungen durchgeführt werden: - ZWICK-Zug-/Druck-Prüfmaschine inklusive Drehmomentmessung - Kraftsensoren - Wegmesssensoren - Koordinatenmessmaschine - Beschleunigungssensoren - Drucksensoren - Analyse- und Präzisionswaagen - Vibrationsprüfstand (Shaker): Erzeugt Vibrationen in unterschiedliche Stufen und Variationen, um eine optimale Transportsimulation zu gewährleisten - Messgeräte für Geräuschmessung und -charakterisierung Umweltprüfung: Sonnensimulator (Xenon), Klimaschränke, Staubkammer Medienbäder PH-Wert-Messgerät Wir erweitern unser bestehendes Equipment stetig. Zögern Sie nicht, nachzufragen!
Mikroskopkamera ODC 851

Mikroskopkamera ODC 851

Die Spezialisten in der Mikroskopie für Messungen, Zählungen, Dokumentation, Archivierung und Bildbearbeitung - Die HDMI-Mikroskopkamera KERN ODC-851 ist speziell für die direkte HDMI-Verbindung zu Ihrem HDMI-fähigen Wiedergabegerät entwickelt worden. Die Bilder können direkt auf die mitgelieferte SD-Karte gespeichert werden oder via USB 2.0-Kabel in Kombination mit der Software OXM 901 an Ihren PC oder Laptop zur weiteren Bearbeitung übertragen werden - Die Stromversorgung erfolgt über eine externe 12 V-Stromeinheit - Lieferumfang ODC 851: Kamera, USB-Maus, USB 2.0 Kabel, HDMI-Kabel, SD-Karte (16 GB) und Microscope VIS Basic KERN OXM 901 Kamerasoftware - Bitte den für Ihr KERN-Mikroskop passenden C-Mount-Adapter gleich mitbestellen Kamera Sensorart: Sony CMOS Kamera Farbtiefe: Farbe Kamera Sensorgröße: 1/2"
SV600 Akustikkamera

SV600 Akustikkamera

Erkennen, lokalisieren und sichtbar machen, was nicht zu hören und nicht zu sehen ist: Luft- und Gaslecks oder Änderungen der Geräuschsignatur in Ihrem Prozess - Minimieren Sie Bedienereingriffe mit einer vollständig automatisierten und integrierten Lösung - Erfassen Sie Daten aus unzugänglichen oder gefährlichen Bereichen, ohne Ihre Mitarbeiter zu gefährden - Überwachen Sie die Änderung von Geräuschsignaturen in Echtzeit, um ungeplanten Wartungsarbeiten vorzubeugen Visualisieren Sie das Ungehörte und das Unsichtbare mit den Möglichkeiten der akustischen Bildgebung. Die Akustikkamera SV600 ermöglicht es den Anwendern, Luft- und Gaslecks oder Änderungen der Geräuschsignatur kontinuierlich zu erkennen, zu lokalisieren und zu visualisieren, bevor sie zu kostspieligen Problemen werden.
KV5-100 MK3 Test System

KV5-100 MK3 Test System

Continuously variable output voltage 0-5kVAC Variable trip circuit 12mA and 20-120mA Output voltage and current metering Visual and audible indication of test piece failure The KV5-100 MK3 Test System is a general purpose, high voltage test instrument designed for testing insulation systems and the measurement of breakdown voltage on electrical plant and components. The unit has an output voltage adjustable from zero to 5kV with accurate metering on both the output voltage and current. A zero-voltage interlock is provided, ensuring that the output may only be energised with the voltage control at zero. The output voltage is metered by a large, linear analogue instrument with a dual-scale marking of 0-3kV and 0-6kV. Load current is metered by a second analogue instrument with 0-10 scale marking. Two current ranges are selectable: 0-10mA and 0-100mA. The test object and output are protected by an adjustable current trip linked to the current metering range. The trip level may be set to 20-120% of the current metering range on 20% steps. Breakdown of the test object is both audibly and visibly indicated. The alarm must be manually reset after a trip condition before testing can be resumed. The KV5-100 MK3 Test System is supplied in a compact and portable case with permanently connected test leads. The test leads are terminated in crocodile clips. The unit is designed to be used in conjunction with an interlocked test enclosure. WEIGHT 16.5 kg DIMENSIONS 364 × 147 × 262 mm SUPPLIED ACCESSORIES Operating manual Mains lead Spare fuse
KV50-20D MK3 Test System

KV50-20D MK3 Test System

0-50kV output voltage 20mA maximum output current Auto-selecting 115/230V supply voltage Key operated supply switch to prevent unauthorised operation Dual overload protection Variable electronic trip Voltage and current metering External interlock circuit Zero-volt interlock Visual indication of test piece failure Cast resin HV transformer The KV50-20D Mk3 Test System is a low power portable high voltage AC test system designed for insulation testing. This system is equally suited to both development and routine testing of electrical insulation systems and plant. The equipment consists of a control unit and a separate resin cast high voltage transformer linked by a 5 metre control cable. The control unit is housed in a rugged aluminium case with a hinged, removable lid for protection. The high voltage transformer is mounted on a base with swivel castors for mobility. The control unit is fitted with a comprehensive range of facilities for control, metering and protection, including an emergency off switch. The output RMS voltage and current are displayed on digital meters. A variable electronic trip is provided, allowing the trip current to be set to 10-110% of rated output. The KV50-20D Mk3 Test System is designed to be operated with the HV transformer inside an interlock test enclosure. A connector is supplied on the control unit to connect interlock switches, extra emergency stop switches and external 24V beacons. WEIGHT 17 kg DIMENSIONS 380 × 314 × 221 mm SUPPLIED ACCESSORIES Operating manual Mains lead Spare fuse
KV30-40D MK3 Test System

KV30-40D MK3 Test System

The output voltage and current are metered by large, accurate true RMS digital meters 0-30kV output voltage 1.2kVA output capability Key operated supply switch to prevent unauthorised operation Dual overload protection Variable electronic trip – 10-110% of rated output Test timer Voltage and current metering Zero-volt interlock External 24Vdc interlock circuit Visual indication of test piece failure The KV30-40D MK3 Test System is a high voltage general purpose test instrument designed for testing insulation systems and the measurement of breakdown voltage on electrical plant and components. The unit has an output voltage variable from zero to 30kV with accurate metering on both the output voltage and current. A zero-voltage interlock is provided, ensuring that the output may only be energised with the voltage control at zero. The output voltage and current are metered by large, accurate true RMS digital meters. The meters are backlit and have a digit height of 19mm. The test object and output are protected by an adjustable current trip. The trip level may be set to 10-110% of the rated output in 10% steps. Breakdown of the test object is visibly indicated. The unit must be manually reset after a trip condition before testing can be resumed. A pre-selectable test timer is provided for timed tests of 5, 10, 15, 20, 30 seconds, 1, 2, 3 or 5 minutes. An alarm sounds when the test time has ended. The units feature automatic mains voltage selection and an external 24Vdc interlock circuit for connection of emergency off switches and enclosure interlocks. WEIGHT 42 kg DIMENSIONS 300 × 400 × 470 mm SUPPLIED ACCESSORIES ES30 earthing stick Supply lead Spare fuse set Operating manual Earth lead
Einfaches Testo-Set zur U-Wert-Bestimmung Testo 635-2

Einfaches Testo-Set zur U-Wert-Bestimmung Testo 635-2

Einsteiger Set von Testo für die einfache U-Wert-Bestimmung. Dieses Starter-Set von Testo enthält alle unbedingt erforderlichen Komponenten sowie einen kleinen, einfachen Koffer. Die U-Wert-Messung erfolgt mit dem Testo 635-2 Feuchtemessgerät. Durch die Verwendung des patentierten 3-Fach U-Wert-Fühlers zur Messung der Wandinnen- und der Raumtemperatur sowie eines Testo Funkfühlers für die Bestimmung von Raumfeuchte, Außenfeuchte und Außentemperatur kann der U-Wert direkt und schnell am Gerät abgelesen werden. Kein aufwendiges Rechnen, keine problematische Messung mit aufwendiger Leitungsverlegung oder langwierigen Messabläufen. Set bestehend aus: - Testo 635-2 mit integriertem Datenspeicher, PC-Schnittstelle und Auswerte-Software - Patentierte 3-Fach-Sonde zur Bestimmung der Differnztemperatur zwischen Innenwand und Innenraum - Haftknete zur Befestigung des Fühler an der Wand - Funkmodul zur Erweiterung des Testo 632-2 um Funkfühler - Funkhandgriff zum Anschluss von Temperatur- und Feuchtefühler über Funk - Raumluft- und Raumfeuchte-Fühler für Funkhandgriff - Einfacher kleiner Koffer passend für Gerät und mitgeliefertes Zubehör. - Netzteil für problemlose Dauermessungen Unsere Empfehlung: Gutes Einstiegs-Set, für die professionelle Nutzung empfehlen wir unser MESSBAR Komplettset 9999 6362 mit Stativ und deutlich hochwertigerem Koffer.
ART3V RELAY TEST SYSTEM

ART3V RELAY TEST SYSTEM

3-f Voltage output from 1-f supply 0-450V f-N output voltage 20VA/phase maximum output Variable Frequency 30-999.9Hz Phase shift ±180.0° Multi-function timing system USB keyboard for comment USB data storage. Ideally suited to testing G59 & G99 schemes Step change of phase and df/dt Large 6.5” back-lit colour LCD Automatic mains voltage selection Fully Programmable test procedures Rugged case and weighs under 9kg The new ART3V Relay Test System brings new features to our range of relay test equipment making it far more adaptable. The new output voltages are higher and have a finer level of accuracy and control. The new full colour LCD provides more test detail, making it easy to understand. The ART3V user interface is an improvement of the DVS3 mk2 allowing simple testing of complex voltage and loss of mains protection systems. The ART3V has vastly improved accuracy, stability, and features. Designed to be the trusted and reliable voltage source for relay testing. The ART3V has been designed using the latest digital technology to generate a highly stable and accurate output with very low distortion. Each phase output is individually adjustable for voltage, frequency and phase angle. The unit is controlled by a simple user interface within defined menus. Values may be either typed in at the capacitive keypad or finely varied using a smooth rotary encoder. Bespoke test procedures can be created for step changes of any output variable at set times or with automatic timing of the response of the relay under test. The ART3V has a colour back-lit display to provide an easy to read user interface. Menu options are selected by dedicated buttons on the panel, allowing easy mode change. All information is displayed including contact set status, and a phasor diagram. The ART3V Relay Test System is ideally suited for testing G59/G99 protection, including loss of mains protection. Vector surge and df/dt (ROCOF) relays can be simply tested and timed, as well as other protection requiring one to three voltages, including: Under and over frequency relays Under and over voltage relays Synchronising relays df/dt & ROCOF relays Vector surge relays Transducers In conjunction with the ART3C or a current source (such as the 200ADM-P), the ART3V can be used to test protection circuits, including: Directional relays Distance protection Phase angle relays Power relays Power transducers Output The output of the ART3V has 4mm safety sockets for phases A, B, C and neutral. The neutral connection may be omitted for a delta connection. The neutrals can be linked for a star connection using the provided accessory. Timing System The timing system on the ART3V is flexible and transparent with different modes of operation. USB Data The ART3V can be connected to a USB keyboard for adding comments to tests. Each test is stored to a USB memory key with each comment. The data is stored in a *.CSV format allowing it to be opened in all types of desktop PC spreadsheet software. Modes of Operation Output Adjust This mode allows full control of frequency, voltage and phase. Phase Lock Mode The frequency and phase of the output can be controlled by an external reference in phase lock mode. The reference may be the mains supply to the ART3V, an external voltage, current. This mode allows testing of directional and distance protection in conjunction with an external current source. Fault Config Mode Fault Config mode allows extra flexibility in testing complex timed events or several sets of values that must be applied to a relay in turn. This mode allows three sets of values to be set in advance (pre-fault, fault, and post-fault values). The ART3V may be set to switch from one state to the next on a change of contact or after a specific time. In addition, the timer may be set to start or stop on any one of the state changes or a change of contact state. This mode allows frequency, phase and voltage to be changed simultaneously if required. Test configurations can be save to USB. More complex configurations can be loaded from the USB, such as a complete G59/G99 relay test, such as relay stability tests. df/dt and ROCOF (Rate Of Change Of Frequency) Loss of mains protection often takes the form of a df/dt relay, sensitive to the rate of change of frequency over time. The ART3V is able to generate a swept frequency output with accurate rates of change of frequency between preset frequencies. WEIGHT 8.9 kg DIMENSIONS 419 × 325 × 195 mm SUPPLIED ACCESSORIES Output lead set Lead set case Mains lead Spare fuse set Operating manual
PV CHECK – PV-Installationstester gemäß VDE 0126-23 (EN 62446)

PV CHECK – PV-Installationstester gemäß VDE 0126-23 (EN 62446)

Isolationswiderstandsmessung 250/500/1000V DC Durchgangsprüfung / Niederohmmessung Rpe Leerlaufspannungsmessung Uoc bis 1000V DC Kurzschlussstrommessung Isc bis 10A DC automatische Anzeige der Spannungspolarität Ergebnisanzeige OK / Nicht OK Funktionstest & Leistungsmessung DC bis 100A DC Wirkungsgrad (optional mit Referenzzelle HT304N) Temperaturmessung (optional mit Fühler PT300N) Einstrahlungsmessung (optional mit Referenzzelle HT304N) Messwertspeicher für 999 Messungen USB Schnittstelle Mit dem PV-CHECKs können alle geforderten elektrischen Sicherheitsprüfungen an Photovoltaik-Systemen einfach, sicher und normgerecht nach VDE 0126-23 (EN 62446) durchgeführt werden. Die einfache Bedienung (Autosequenz Messablauf) ermöglicht eine sichere, zuverlässige und schnelle Durchführung aller geforderten Messungen (automatischer Prüfablauf): Kurzschlussstrom → Leerlaufspannung → Isolationsmessung → Niederohmmessung Funktionen: Isolationswiderstandsmessung 250/500/1000V DC mit Riso Einzelmessung + oder – gegen Erde Durchgangsprüfung / Niederohmmessung Rpe Leerlaufspannungsmessung Uoc bis 1000V DC Kurzschlussstrommessung Isc bis 15A DC automatische Anzeige der Spannungspolarität Ergebnisanzeige OK / Nicht OK Funktionstest & Leistungsmessung DC bis 100A Datenlogger Funktion DC Wirkungsgrad (optional mit Referenzzelle HT304N) Temperaturmessung (optional mit Fühler PT300N) Einstrahlungsmessung (optional mit Referenzzelle HT304N) inkl. Messwertspeicher für 999 Messungen inkl. USB Schnittstelle
20A DC booster Winding resistance test

20A DC booster Winding resistance test

Maximum output current: 20 A DC Maximum power on output sockets: 400 W Current output switch: controlled by STCS Current output amplitude: controlled by STS 5000 or STS 4000 The 20A DC STCS booster allows to perform resistance tests on a PT with a current up to 20 A DC. The option is used together with STS 5000 and STS 4000 and must be connected to STCS module.
HV TROLLEY2 High Voltage AC Test System

HV TROLLEY2 High Voltage AC Test System

20kVA output capability 0-3kV to 0-15kV options available Accurate digital metering Key operated supply switch Dual overload protection Variable electronic trip 10-110% of rated output Voltage and current metering Optional 5s – 5min test timer External 24V interlock and zero-volt interlock Emergency stop switch The HV trolley2 series of units are high power AC flash test sets with a 20kVA output capability. Single Trolley Version The maximum output voltage can be customised to be any voltage up to 15kV. The unit is housed in a rugged aluminium enclosure with a cover to protect the control panel. It is mounted on wheels to allow easy movement within a production environment. The HV trolley2 is provided with accurate digital voltage and current metering and a variable electronic trip. An external interlock input is also fitted to the unit. Outputs are provided to drive 24V warning beacons. The HV output is connected to the test object by a high voltage cable 5m long.
Testo 835-H1 Infrarot-Temperatur/Feuchte-Messgerät

Testo 835-H1 Infrarot-Temperatur/Feuchte-Messgerät

Neues, hochgenaues Infrarot-Messgerät mit ein paar ganz besonderen Funktionen: - Möglichkeit zur automatischen Emissionsgrad-Bestimmung, sofern ein optionaler Oberflächenfühler mit angeschlossen ist - Berechnung des aW-Wertes für die Schimmel-Wahrscheinlichkeits-Beurteilung aus der gemessenen Oberflächentemperatur und der Raumfeuchtigkeit - Online-Messung über einen PC und die kostenlos herunterladbare Software Das präzise, leicht zu bedienende Infrarot-Messgerät mit Feuchtemodul aus der neuen Testo 835 Serie mit 4-Punkt-Laser und integriertem Messwertspeicher. Die abgespeicherten Daten können anschließend am PC bequem ausgewertet werden. Sogar Online-Messungen über den PC sind mit diesem Gerät möglich. Dabei wird die Messung vom PC aus gestartet und der Messwert sofort am PC angezeigt. Das neue Testo 835-H1 mit patentierter Infrarot-Oberflächenfeuchtemessung (es wird die Oberflächen-Feuchte-Wahrscheinlichkeit durch das Gerät berechnet und angezeigt) und einer Optik von 50:1 ideal für die Raumfeuchte-Beurteilung im Bauhandwerk. Es verfügt zusätzlich über eine integrierte Emissionsgrad-Tabelle und eine automatische Emissionsgrad-Berechnung. Ein Typ K-Temperaturfühler kann bei Bedarf angeschlossen werden (Fühler nicht im Lieferumfang enthalten). Technische Daten: Optik 50:1 Blick 4-Punkt-Laser Spektralbereich 8 bis 14 µm Messbereich Infrarot -30 bis +600 °C Genauigkeit +/-2,5 °C (-30 bis -20,01 °C), +/-1,5 °C (-20 bis 0,1 °C) +/-1,0 °C (0,0 bis 99,9 °C), +/-1% v. Mw. Auflösung 0,1 °C Messbereich Sensortyp Typ K (NiCr-Ni) -50 bis +600°C Genauigkeit +/- (0,5 °C + 0,5% v. Mw.) Auflösung 0,1 °C Messbereich Feuchtesensor kapazitiv 0 bis 100% rF Genauigkeit +/- 1 Digit +/-2 % rF, +/-0,5 °C Auflösung 0,1 °C, 0,1 %rF, 0,1 °Ctd Emissionsfaktor 0,1 bis 1,00 (Schritt 0,01) Emissionsgradtabelle 20 Messwerte speicherbar Laserpunkt Ein/Aus Speicher 200 Messwerte speicherbar Alarm IR-Temperatur, TE-Temperatur Alarmsignal akustisch, optisch Betriebstemperatur -20 bis +50°C Lagertemperatur -30 bis +50°C Gehäusematerial ABS + PC BatterieTyp 3 x Batterie Typ AA (oder USB-Anschluss mit PC-Software Abmessung (LxHxB) 193 x 165 x 63 mm Gewicht 514 g Display Dot-Matrix Garantie 2 Jahre Testo 835-H1, Infrarot-Temperatur-Messgerät, 4-Punkt-Lasermarkierung, Messdatenverwaltung, Feuchtemodul, inkl. Batterien und Kalibrierprotokoll Dieses Gerät ergänzt die Serie von Temperatur- und Feuchte-Messgeräten bei Testo ganz hervorragend. Für den Bausachverständigen ein ideales Gerät, wir empfehlen unbedingt die Kombination mit dem Kreuzband Oberflächen-Fühler von Testo.
Testo 835-H1 Infrarot-Temperatur/Feuchte-Messgerät

Testo 835-H1 Infrarot-Temperatur/Feuchte-Messgerät

Neues, hochgenaues Infrarot-Messgerät mit ein paar ganz besonderen Funktionen: - Möglichkeit zur automatischen Emissionsgrad-Bestimmung, sofern ein optionaler Oberflächenfühler mit angeschlossen ist - Berechnung des aW-Wertes für die Schimmel-Wahrscheinlichkeits-Beurteilung aus der gemessenen Oberflächentemperatur und der Raumfeuchtigkeit - Online-Messung über einen PC und die kostenlos herunterladbare Software Das präzise, leicht zu bedienende Infrarot-Messgerät mit Feuchtemodul aus der neuen Testo 835 Serie mit 4-Punkt-Laser und integriertem Messwertspeicher. Die abgespeicherten Daten können anschließend am PC bequem ausgewertet werden. Sogar Online-Messungen über den PC sind mit diesem Gerät möglich. Dabei wird die Messung vom PC aus gestartet und der Messwert sofort am PC angezeigt. Das neue Testo 835-H1 mit patentierter Infrarot-Oberflächenfeuchtemessung (es wird die Oberflächen-Feuchte-Wahrscheinlichkeit durch das Gerät berechnet und angezeigt) und einer Optik von 50:1 ideal für die Raumfeuchte-Beurteilung im Bauhandwerk. Es verfügt zusätzlich über eine integrierte Emissionsgrad-Tabelle und eine automatische Emissionsgrad-Berechnung. Ein Typ K-Temperaturfühler kann bei Bedarf angeschlossen werden (Fühler nicht im Lieferumfang enthalten). Technische Daten: Optik 50:1 Blick 4-Punkt-Laser Spektralbereich 8 bis 14 µm Messbereich Infrarot -30 bis +600 °C Genauigkeit +/-2,5 °C (-30 bis -20,01 °C), +/-1,5 °C (-20 bis 0,1 °C) +/-1,0 °C (0,0 bis 99,9 °C), +/-1% v. Mw. Auflösung 0,1 °C Messbereich Sensortyp Typ K (NiCr-Ni) -50 bis +600°C Genauigkeit +/- (0,5 °C + 0,5% v. Mw.) Auflösung 0,1 °C Messbereich Feuchtesensor kapazitiv 0 bis 100% rF Genauigkeit +/- 1 Digit +/-2 % rF, +/-0,5 °C Auflösung 0,1 °C, 0,1 %rF, 0,1 °Ctd Emissionsfaktor 0,1 bis 1,00 (Schritt 0,01) Emissionsgradtabelle 20 Messwerte speicherbar Laserpunkt Ein/Aus Speicher 200 Messwerte speicherbar Alarm IR-Temperatur, TE-Temperatur Alarmsignal akustisch, optisch Betriebstemperatur -20 bis +50°C Lagertemperatur -30 bis +50°C Gehäusematerial ABS + PC BatterieTyp 3 x Batterie Typ AA (oder USB-Anschluss mit PC-Software Abmessung (LxHxB) 193 x 165 x 63 mm Gewicht 514 g Display Dot-Matrix Garantie 2 Jahre Testo 835-H1, Infrarot-Temperatur-Messgerät, 4-Punkt-Lasermarkierung, Messdatenverwaltung, Feuchtemodul, inkl. Batterien und Kalibrierprotokoll Dieses Gerät ergänzt die Serie von Temperatur- und Feuchte-Messgeräten bei Testo ganz hervorragend. Für den Bausachverständigen ein ideales Gerät, wir empfehlen unbedingt die Kombination mit dem Kreuzband Oberflächen-Fühler von Testo.
MultiTest HT700 – ARC DGUV Vorschrift 3 Tester mit Touchscreen

MultiTest HT700 – ARC DGUV Vorschrift 3 Tester mit Touchscreen

DGUV V3 Gerätetester zur Prüfung elektrischer Betriebsmittel inkl Schweißgeräte Prüfung im Rahmen der DGUV V3, BetrSichV gemäß: • DIN VDE 0701-02:2008 (EN 62638) Prüfung elektrischer Geräte/Arbeitsmittel • DIN VDE 0751-1:2015 (EN 62353): Prüfung medizinisch elektrischer Geräte, wie Pflegebetten etc. • DIN VDE 0544-4 (EN 60974-4): Prüfung elektrischer Schweißgeräte Leistungsmerkmale: • Prüfung von mobilen Personenschutzschaltern PRCD (2-/3-polig) Typ S, S+, K • Prüfung von Fehlerstromschutzeinrichtungen RCD Typ AC, A, F, B, B+ • Schnittstellen: WLAN, RJ45 (LAN), USB, SD-Kartenslot und Bluetooth® • Standard, erweiterte und kundenspezifische Sichtprüfungen • Prüfung von Lichtbogenschweißeinrichtungen • Gerätetester kann in IT-Netzen betrieben werden • Datenbankverwaltung von Kunden & Betriebsmitteln mit ID-Nr. • Erstellung und Zuweisung individueller Prüfabläufe und -intervalle • Automatischer und manueller Prüfablauf einstellbar • Geringe Betriebskosten, kostenfreie Updates über WLAN, LAN, USB • Touch-Screen für Gesten, Softkey-Tastatur (QWERTZ), grafische Bedienfelder, „On-/Off-Slider“ zum Aktivieren/Deaktivieren von Funktionen • Unbegrenzte Datenspeicherung über SD-Karte • Messergebnis mit eindeutiger GUT / SCHLECHT Anzeige • Komplett – ein Gerätetester für alle VDE Geräteprüfungen
Testo 816-1 Schallpegelmessgerät Klasse 2 mit Datenlogger

Testo 816-1 Schallpegelmessgerät Klasse 2 mit Datenlogger

Das neue Testo 816-1 mit Datenspeicher und Software, jetzt nach neuer Norm, gemäß IEC 61672-1 Klasse 2 (vergleichbar zur nicht mehr gültigen DIN 60641) und ANSI S1.4 Typ 2 Das ideale Schallpegelmessgerät der Klasse 2 für die verschiedensten Einsatzbereiche wie z.B.am Arbeitsplatz, in Industrie- und Fertigungshallen oder auch an öffentlichen Plätzen. Das neue Messgerät ist einfach zu bedienen. So kann mit einem einfachen Tastendruck die Frequenzbewertung von A (Schalldruckempfinden des menschlichen Ohres) zu C (niederfrequente Geräuschanteile) gewechselt werden, oder die Messzeit von Slow auf Fast verändert werden. Mittels der im Lieferumfang enthaltenen Software können die gespeicherten Daten (Datespeicher 3000 Messwerte) bequem am PC verwaltet werden. Mit dem optional erhältlichen Schallkalibrators kann das Schallmessgerät vor Ort nachkalibriert werden, wodurch Sie eine höchste Genauigkeit der ermittelten Messwerte sicher stellen.Bitte beachten Sie, dass der Schallkalibrator nicht im Lieferumfang enthalten ist und bei Bedarf zusätzlich bestellt werden muss. Technische Daten: Frequenzbereich: 20Hz - 8.000 Hz (gemäß Klasse 2) Speicher ca. 31 000 Messwerte Schallmessbereich 30 bis 130 dB Genauigkeit +/- 1,4 dB Auflösung 0,1 dB Beleuchtetes Display Lagertemperatur -10 bis +60°C Betriebstemperatur 0 bis +40°C 4x Mignonzellen Typ AA Abmessungen 272 x 83 x 42 mm Lieferumfang: - Schallmessgerät Testo 816-1inkl. Mikrofon - Windschutz - Software mit PC-Verbindungskabel (engl.Sprache) - Bedienungsanleitung auf CD-ROM - Batterien -Systemkoffer
Testo 816-1 Schallpegelmessgerät Klasse 2 mit Datenlogger

Testo 816-1 Schallpegelmessgerät Klasse 2 mit Datenlogger

Das neue Testo 816-1 mit Datenspeicher und Software, jetzt nach neuer Norm, gemäß IEC 61672-1 Klasse 2 (vergleichbar zur nicht mehr gültigen DIN 60641) und ANSI S1.4 Typ 2 Das ideale Schallpegelmessgerät der Klasse 2 für die verschiedensten Einsatzbereiche wie z.B.am Arbeitsplatz, in Industrie- und Fertigungshallen oder auch an öffentlichen Plätzen. Das neue Messgerät ist einfach zu bedienen. So kann mit einem einfachen Tastendruck die Frequenzbewertung von A (Schalldruckempfinden des menschlichen Ohres) zu C (niederfrequente Geräuschanteile) gewechselt werden, oder die Messzeit von Slow auf Fast verändert werden. Mittels der im Lieferumfang enthaltenen Software können die gespeicherten Daten (Datespeicher 3000 Messwerte) bequem am PC verwaltet werden. Mit dem optional erhältlichen Schallkalibrators kann das Schallmessgerät vor Ort nachkalibriert werden, wodurch Sie eine höchste Genauigkeit der ermittelten Messwerte sicher stellen.Bitte beachten Sie, dass der Schallkalibrator nicht im Lieferumfang enthalten ist und bei Bedarf zusätzlich bestellt werden muss. Technische Daten: Frequenzbereich: 20Hz - 8.000 Hz (gemäß Klasse 2) Speicher ca. 31 000 Messwerte Schallmessbereich 30 bis 130 dB Genauigkeit +/- 1,4 dB Auflösung 0,1 dB Beleuchtetes Display Lagertemperatur -10 bis +60°C Betriebstemperatur 0 bis +40°C 4x Mignonzellen Typ AA Abmessungen 272 x 83 x 42 mm Lieferumfang: - Schallmessgerät Testo 816-1inkl. Mikrofon - Windschutz - Software mit PC-Verbindungskabel (engl.Sprache) - Bedienungsanleitung auf CD-ROM - Batterien -Systemkoffer
Nemo SX Three Phase module through Rogowski sensors (125A max) SXMT125

Nemo SX Three Phase module through Rogowski sensors (125A max) SXMT125

Multifunction measuring module delivered with n°3 centering plastic supports and flexible Rogowski coils to measure a three phase circuit up to 630 A AUX derived from the SXAA230 power supply module FORMAT 1 DIN module CURRENT minima 12,5 A, base 250 A, massima 630 A VOLTAGE 110…500 V phase-phase VOLTAGE OPTIONS direct CURRENT OPTIONS da 3 bobine flessibili e apribili Rogowski Ø50 mm TYPE Multifunction measuring module delivered with n°3 centering plastic supports and flexible Rogowski coils to measure a three phase circuit up to 630 A MAIN three-phase 3/4 wire unbalanced load DISPLAY None Module dedicated to Nemo SX System. Multifunction Measuring module for high currents. Measures the main electrical data of a single–phase or three–phase network. The insertion is done by open flexible Rogowski coils.
HT-MK4 Adapterkoffer 3 Phasen 32A zur aktiven und passiven Prüfung

HT-MK4 Adapterkoffer 3 Phasen 32A zur aktiven und passiven Prüfung

Zur komfortablen Prüfung von CEE Verlängerungsleitungen (Rpe, Riso, IEA, Verdrahtung) und aktiver Prüfung 3-phasiger Verbraucher (Differenzstrommessung) Bei Verlängerungsleitungen mit Funktions- und Drehfeldprüfung Anschluss: 16 A CEE 5-polig zur aktiven Prüfung 3-phasiger Verbraucher unter Funktion Rpe, Riso, Ipe/Ib (Ersatz-, Differenz-, direktes Verfahren) zur aktiven Prüfung von Schweißgeräten
Mikroskopkamera ODC 852

Mikroskopkamera ODC 852

Die Spezialisten in der Mikroskopie für Messungen, Zählungen, Dokumentation, Archivierung und Bildbearbeitung - Die HDMI-Autofokus-Kamera ODC 852 bietet Ihnen eine perfekte und effektive Lösung für die moderne Mikroskopie. Durch die Autofokus-Funktion wird die Fokusebene automatisch erkannt und eingestellt, sodass Sie stets ein messerscharfes Bild erhalten. Ideal für alle Anwendungen in Verbindung mit einem KERN-Stereomikroskop - Die Echtzeit-Bilder der ODC 852 können sowohl mit der HDMI-Verbindung direkt auf ein HDMI-fähiges Wiedergabegerät transferiert als auch auf die mitgelieferte SD-Karte gespeichert werden. Alternativ kann die Datenübertragung auch per WLAN-Modul (ODC 852) oder USB 2.0-Kabel an einen PC oder Laptop in Kombination mit der im Lieferumfang enthaltenen KERN OXM 902 Software erfolgen - Die Stromversorgung erfolgt über eine externe 12 V-Stromeinheit - Lieferumfang ODC 852: Kamera, USB-Maus, HDMI-Kabel, SD-Karte (16 GB), WLAN-Adapter und Microscope VIS Pro KERN OXM 902 Kamerasoftware - Bitte den für Ihr KERN-Mikroskop passenden C-Mount-Adapter gleich mitbestellen Kamera Sensorart: Sony CMOS Kamera Farbtiefe: Farbe Kamera Sensorgröße: 1/1, 8"
Mikroskopkamera ODC 874

Mikroskopkamera ODC 874

Die Spezialisten in der Mikroskopie für Messungen, Zählungen, Dokumentation, Archivierung und Bildbearbeitung - Mit den KERN Okularkameras können Sie Ihr gewöhnliches Mikroskop in ein digitales Mikroskop verwandeln, indem Sie ein Okular Ihres nicht-digitalen Mikroskops durch die Okularkamera ersetzen und dieses per USB an Ihren Computer anschließen - Die Okularkameras sind universell einsetzbar und über USB-Kabel (USB 2.0) an das Mikroskop sowie an einen Laptop oder PC anzuschließen - Die Stromversorgung erfolgt durch das USB-Kabel, sodass keine zusätzliche Stromversorgung benötigt wird - Eine optimale Synchronisation, eine hohe Bildrate sowie eine stabile Bildperformance wird in Verbindung mit unserer mitgelieferten Software Microscope VIS Ihre tägliche Arbeit wesentlich erleichtern - Im Lieferumfang befindet sich neben der Kamera eine vereinfachte Version unserer mehrsprachigen Kamerasoftware Microscope VIS KERN OXM 901, ein USB-Kabel (Länge: 1,5 m), zwei Okularadapter und ein Objekt-Mikrometer zur Kalibrierung der Software - Mögliche Tubusdurchmesser: 23,2 mm (Standard) 30,0 mm (Okularadapter) 30,5 mm (Okularadapter) - Auflösung Kamera 3,1 MP Kamera Sensorart: Aptina CMOS Kamera Farbtiefe: Farbe Kamera Sensorgröße: 1/2,5" Kamera Auflösung: 3,1 MP